Custom Speakers & Microphones, Engineered and Built Under One Roof.
One team owns the driver, the enclosure and the test data. 377 standard parts in the catalogue, plus custom programs from a 9 mm micro speaker to a 15-inch woofer.
A curve is only useful if it describes the part you will actually receive. Every datasheet we send is measured on our own bench, on production-intent samples, with the test conditions written down.
01
T/S parameters per build batch
fs, Qts and Vas measured by the impedance method on the batch you receive — not copied from a family datasheet.
02
Sweeps at 1 / 5 / 10 W
Power sweeps show compression and distortion before the part reaches your enclosure.
03
Environmental screens
Temperature, humidity, salt spray and life testing matched to the target market.
Application, SPL target, space and amplifier defined together.
02
Acoustic & mechanical design
Driver geometry and enclosure volume designed as one system.
03
Prototype
3D-printed and machined shells before steel is cut.
04
Tuning & test
T/S parameters, curves and listening checks on our bench.
05
Tooling
Injection moulds with DFM review and gate approval.
06
Production
Pilot build, EOL testing and batch traceability.
PROJECT NOTE
A 12 mm Soundbar Module, Recovered in Five Weeks
The customer’s original module went hollow and thin below 300 Hz once the industrial design team shaved 6 mm off the enclosure. Re-tuning the driver and re-venting the chamber recovered the bass — without moving the outside dimensions.
Ten industries, one discipline: the part is specified against the environment it will live in — heat, moisture, drop, dust or a customer tapping it every day.
The Sample and the Shipment Come Off the Same Line
Volume is run with the same discipline the sample was approved under: the same fixtures, the same limits, the same test station. No second process appears after the PO.
Pilot build with written acceptance limits before mass production
End-of-line acoustic test on every production unit
Batch traceability from magnet assembly to packed carton
Engineering change control — no silent spec revisions
ISO 9001:2015 · ISO 14001:2015 · CE · FCC · RoHS · REACH